Rexroth A2f A2fo A2FM A2fe Hydraulic Pump and Motor for Metallurgical Machinery

Rexroth A2f A2fo A2FM A2fe Hydraulic Pump and Motor for Metallurgical Machinery

CZPT CZPT Motor A2FE Series

A2FE180 hydraulic motor new manufacturer manufactured in Germany
 
CZPT set motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open and shut circuits
Series sixty one and 60
Strain:
Measurement 28 to180 Nominal force 5800 psi (400 bar)/ Peak strain 6500 psi (450 bar)
Size 250 to 355 Nominal stress 5100 psi (350 bar)/ Peak pressure 5800 psi (four hundred bar)
 
The A2FE set plug-in motor with axial tapered piston rotary team of bent-axis design and style, for hydrostatic drives in open up and shut circuits
-Far-achieving integration in mechanical gearbox thanks to recessed mounting flange situated in the center of the circumstance (extremely room-preserving construction)
-The output pace is dependent on the movement of the pump and the displacement of the motor.
-The output torque will increase with the force differential amongst the higher-pressure and the reduced-pressure facet.
-Small dimensions.
-Higher overall effectiveness.
-CZPT device, prepared-assembled and analyzed.
-Straightforward to install, merely plug into the mechanical gearbox.
-No configuration technical specs to be observed when installing.
 
CZPT Data 
Desk of values (theoretical values, with no effectiveness and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.1 32 forty five.6 56.1 63 80.four  
Speed optimum nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Input flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = four hundred bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad 2.93 three.12 four.18 5.94 6.25 eight.73  
Minute of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Maximum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Scenario volume V  L .2 .two .33 .45 .45 .55  
Mass (approx.) m kg ten.5 ten.five fifteen eighteen 19 23  
Dimension A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 ninety 106.7 a hundred twenty five a hundred and sixty.4 one hundred eighty 250 355
Speed greatest nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Input movement qV L/min 405 427 five hundred 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = 400 bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad nine.fourteen 11.2 11.nine 17.4 eighteen.two 73.one 96.one
Moment of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Optimum angular a rad/s2 6000 4500 4500 3500 3500 ten thousand 8300
Situation volume V L .fifty five .eight .8 1.1 one.one 2.five three.five
Mass (approx.) m kg twenty five 34 36 47 forty eight 82 one hundred ten

CZPT fluid
Before beginning undertaking plHangZhou, you should refer to our knowledge sheets RE 95710 (mineral oil), RE 95711 (environmentally suitable hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for detailed data concerning the option of hydraulic fluid and application conditions. The plug-in motor A2FE is not ideal for procedure with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally satisfactory hydraulic fluids are utilised, the limitations relating to technological information or other seals must be noticed.
Information regarding the selection of hydraulic fluid
The right selection of hydraulic fluid requires understanding of the working temperature in relation to the ambient temperature: in a shut circuit, the circuit temperature, in an open circuit, the reservoir temperature. The hydraulic fluid need to be decided on so that the working viscosity in the working temperature variety is inside of the the best possible selection (νopt), see shaded spot of the choice diagram. We recommended that the higher viscosity class be selected in each circumstance. Illustration: At an ambient temperature of X °C, an functioning temperature of 60 °C is established in the circuit. In the optimum running viscosity selection (νopt., shaded area) this corresponds to the viscosity courses VG 46 or VG sixty eight to be selected: VG 68.
Observe: The scenario drain temperature, which is influenced by pressure and speed, can be higher than the circuit temperature or reservoir temperature. At no point of the element could the temperature be greater than one hundred fifteen °C. The temperature difference specified underneath is to be taken into account when deciding the viscosity in the bearing. If the above circumstances can’t be preserved because of to extreme functioning parameters, we advise the use of a flushing and boost strain valve.
Shaft seal
Permissible pressure loading the service life of the shaft seal is affected by the speed of the axial piston device and the case drain stress (circumstance stress). The mean differential pressure of 2 bar in between the circumstance and the ambient stress might not be enduringly exceeded at typical operating temperature. For a larger differential force at reduced velocity, see diagram. Momentary pressure spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 

Rexroth A2f A2fo A2FM A2fe Hydraulic Pump and Motor for Metallurgical Machinery